• Use with AQ1000 2-wire dry contact communicating thermostats and most digital thermostats.
• 0-10 Vdc modulating output for driving a modulating/condensing boiler.
• Displays outdoor temperature on all AQ1000 Series thermostats when used with an AQ12C10 outdoor sensor (included).
• Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install").
• Customizable control settings and schedules allow for greater level of control and comfort.
• Controls up to 2 stages of heat from a single thermostat.
• Central programming of zone set points and setbacks
• Zoning Control for up to 4 zones as shipped; can be expanded to a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones when used with AQ254 Add-a-Temperature panels.
• Zone synchronization through Zone of Greatest Demand control.
• Domestic hot water priority and priority override protection.
• Line or low-voltage output for zoning equipment (pumps or valves).
• Boiler short cycling protection.
• Boiler post purge.
• Freeze protection.
• Pump/valve exercise.
• Boiler shock prevention from cold water returning to boiler.
• Automated test and purge feature for quick start-up and simplified troubleshooting.
• Integral 38 VA transformer with self resetting electronic fuse.
• 2 hour power supply (super-capacitor) to retain day and time settings during power outage.
• Non-volatile EPROM memory retains program settings during power outage.PROGRAMMABLE RELAY CONTROL PANEL FOR 4 ZONES OF PUMPS OR ZONE VALVES (WITHOUT END SWITCHES).

ApplicationBoiler control for zoned hydronic systems
Setback Program7 day, up to 2 setback periods/day.
Boiler Differential2F to 41F (1C to 23C), or Auto (minimum 2 minutes on time)
User Interface (Setting, Programming)DIP Switches on zoning modules
OverviewThe AQ25A family of AQUATROL Programmable Relay Boiler Controls provides simplified, energy-efficient control of single-temperature, residential hydronic heating systems. The AQ25A easily converts a single zone heating system into a room-by-room comfort c
List Price683.03
Number of Zones Controlled4
Boiler Heat Post PurgeOff, 10 seconds to 30 minutes (factory default is 30 seconds)
Pump/Valve exercise30 seconds per 2 weeks of space heating inactivity
Power Supply120V/60Hz
Thermostat CompatibilityAQ1000 Series 2-wire communicating thermostats and most digital thermostats
R-C Output (on transformer)38 VA, 24 Vac Class II
R-C Input (on Control and Zoning Modules)24 Vac Class II (input on Control and Zoning Modules)
Supply/Return SensorLead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire
Auxiliary (Demand) InputExternal dry contacts connection only
Heat Demand (Thermostat R-W) InputExternal dry contacts connection only
DHW Demand InputExternal dry contacts connection only
Boiler (T-T) Output Rating24 Vac, 0.5A, 12VA
Auxiliary Low Voltage Output Rating24 Vac, 0.5A, 12VA
B-B Communication Bus TerminalsLow voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules.
Zone Module Thermostat inputLow voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat.
Boiler Pump Output Rating120 Vac/250 Vac 5A, 1/3HP
DHW Pump/Valve Output Rating120 Vac/250 Vac 5A, 1/3HP
Auxiliary Pump Output RatingDry contact output, 120 Vac/250 Vac 5A, 1/3 HP
Zone Output Contact RatingPumps: 120 Vac/250 Vac, 5A, 1/3 HP
Control and Zoning Panel Temperature Rating (F)32 F to 130 F
Control and Zoning Panel Temperature Rating (C)0 C to 55 C
Sensor Temperature Rating (F)-58 F to +230 F
Sensor Temperature Rating (C)-50 C to +110 C
Dimensions (in.)16 1/2 in wide x 8 in. high x 3 3/8 in deep
Weight (kg)2.6 kg
Operating Humidity Range (% RH)5 to 90% RH, non-condensing
Weight (lb)5.7 lbs
Dimensions (mm)42 cm wide x 20.3 cm high x 8.5 cm deep
Tradeline ValueTradeline
Type of Zoning Devices ControlledZone pumps or 2-wire valves (line voltage)
Electrical Connections (Line Voltage)Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals
Outdoor SensorLead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892.
Replacement PartsAQ10X38 24 Vac 38 VA transformer
Approvals, Canadian Standards AssociationCSA C/US Certified to CSA and UL Standards, File No. LR76030

Product Family

Model NumberDecriptionManufacturerPriceAvail. Qty 
AQ25A42B PROGRAMMABLE RELAY CONTROL PANEL FOR 4 ZONES OF PU Honeywell, Inc. Call for Pricing 0    View More Info

Coming Soon

All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.

UPS Hoilday Delivery Schedule

For more infomation about Returns visit Returns

For more informatrion about Warranty visit Warranty page.

You can also find answers to some common questions on our FAQ page

Reviews

Not reviewed yet, be the first to write one!

Add Review