• AQ255 for zoning with pumps or zone valves without end switches.
• Auto test function to test zones at system start up. It allows for operator controlled testing of zones; includes pause/restart capability.
• LED lights for visual diagnostic of zone operation.
• Allows zoning with either "Normally Open" or "Normally Closed" zone valves.
• Adjacent zoning panels can operate different zone equipment - one panel may control 4 pumps while another may control 4 zone valves.
• Easily switch from zone valves to pumps with same zoning module - just flip one DIP switch. Ensure correct voltage is applied to all zone equipment on a panel (120 Vac for pumps, 24 Vac for valves)
• R-C transformer and B-B data bus terminal connections (network communication) for easy expansion.
• Zones can be set to energize a group pump via Aux Out dry contacts on main control panel (AQ250, AQ25A, AQ251, AQ252) or expansion control panel (AQ254).
• Zone synchronization through Zone of Greatest Demand control.
• 38 VA Transformer with self resetting electronic fuse.ZONING PANEL FOR 4 PUMPSApplication | Zoning control for hydronic zoning system |
---|
User Interface (Setting, Programming) | DIP Switches |
---|
Overview | The AQ255 and AQ257 family of AQUATROL Expansion Zoning panels work with AQ2000 Boiler Control Panels and AQ1000 Communicating Thermostats to control up to 4 space heating zones (or 8, for the AQ25582B Panel). Can be combined with additional expansion zon |
---|
Number of Zones Controlled | 4 |
---|
Thermostat Compatibility | AQ1000 Series 2-wire communicating thermostats and most digital thermostats |
---|
R-C Input (on Control and Zoning Modules) | 24 Vac Class II (input on Control and Zoning Modules) |
---|
B-B Communication Bus Terminals | Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules. |
---|
Zone Module Thermostat input | Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat. |
---|
Zone Output Contact Rating | 120 Vac/250 Vac, 5A, 1/3 HP |
---|
Control and Zoning Panel Temperature Rating (F) | 32 F to 130 F |
---|
Control and Zoning Panel Temperature Rating (C) | 0 C to 55 C |
---|
Dimensions (in.) | 9 1/2 in wide x 8 in. high x 3 3/8 in. deep |
---|
Operating Humidity Range (% RH) | 5 to 90% RH, non-condensing |
---|
Dimensions (mm) | 24 cm wide x 20.3 cm high x 8.5 cm deep |
---|
Type of Zoning Devices Controlled | Zone pumps or 2-wire valves (line voltage) |
---|
Electrical Connections (Line Voltage) | Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals |
---|
Replacement Parts | AQ15540B 4-zone pump expansion module |
---|
Approvals, Canadian Standards Association | CSA C/US Certified to CSA and UL Standards, File No. LR76030 |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|