Spring, 90in-lb, MFT, 24V, SWServicing | maintenance free |
---|
Power Supply | 24 VAC�20%, 50/60Hz, 24 VDC+20%/-10% |
---|
Power Consumption Running | 6.5 W |
---|
Power Consumption Holding | 3 W |
---|
Transformer Sizing | 9 VA (class 2 power source) |
---|
Electrical Connection | (2) 3 ft [1 m], 18 GA appliance cables with 1/2? conduit connectors |
---|
Overload Protection | electronic throughout 0� to 95� rotation |
---|
Input Impedance | 100 k ? for 2 to 10 VDC (0.1 mA), 500 ? for 4 to 20 mA, 1500 ? for PWM, floating point and On/Off |
---|
Angle of Rotation | 95� (adjustable with mechanical end stop, 35� to 95�) |
---|
Direction of Rotation (Motor) | reversible with built-in switch |
---|
Manual Override | 5 mm hex crank (3/16? Allen), supplied |
---|
Running Time (Motor) | 150 sec (default), variable (40 to150 sec) |
---|
Ambient Temperature Range | -22�F to +122�F [-30�C to +50�C] |
---|
Storage Temperature Range | -40�F to +176�F [-40�C to +80�C] |
---|
Housing | NEMA 2, IP54, UL enclosure type 2 |
---|
Agency Listings | cULus acc. to UL60730-1A/-2-14, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/EC |
---|
Noise Level (Motor) | �40 dB (A) @ 150 sec, run time dependent |
---|
Operating Range Y | 2 to 10 VDC, 4 to 20 mA w/ ZG-R01 (500 ?, 1/4 W resistor), variable (VDC, PWM, floating point, on/off) |
---|
Direction of Rotation (Fail-Safe | reversible with CW/CCW mounting |
---|
Position Indication | visual indicator, 0� to 95� (0� is full spring return position) |
---|
Running Time (Fail-Safe) | <20 sec @ -4�F to 122�F [-20�C to 50�C], <
60 sec @ -22�F [-30�C] |
---|
Noise Level (Fail-Safe) | <62 dB (A) |
---|
Feedback Output U | 2 to 10 VDC, 0.5 mA max, VDC variable |
---|
Housing Material | zinc coated metal and plastic casing |
---|
Electrical protection | actuators are double insulated |
---|
Angle of Rotation Adaptation | Off (default) |
---|
Override Control | min. position = 0% , mid. Position = 50% , max. position = 100% (Default) |
---|
Humidity | max. 95% RH non-condensing |
---|
Auxiliary Switch | 2 x SPDT, 3A resistive (0.5A inductive) @ 250 VAC, one set at +10�, one adjustable 10� to 90� |
---|
Shaft Diameter | 1/2? to 1.05? round, centers on 1/2? and 3/4? with insert, 1.05? without insert |
---|
Torque | 90 in-lbs [10 Nm] minimum |
---|
MFT-P | Actuator power supply and control simulator. |
---|
ZK2-GEN | Handheld programming tool w/ ZK1-GEN, ZK2-GEN, ZK6-GEN. |
---|
AF-P | Anti-rotation bracket AF/NF |
---|
SH8 | 8 mm and 10 mm wrench. |
---|
ZG-100 | Univ. right angle bracket (13? H x 11? W x 7-7/16? base). |
---|
ZG-101 | Right angle bracket for ZS-260. |
---|
ZG-DC1 | Damper clip for damper blade, 6? width. |
---|
ZG-DC2 | 1? diameter jackshaft adaptor (11? L). |
---|
ZS-100 | Base plate for ZS-100. |
---|
ZS-150 | Explosion proof housing. |
---|
ZS-260 | NEMA 4X, 304 stainless steel enclosure. |
---|
ZS-300 | NEMA 4X, 316L stainless steel enclosure. |
---|
TOOL-06 | Classic AF/NF to AFB(X)/NFB(X) retrofit mounting bracket |
---|
AV8-25 | 9.8? shaft extension for 5/16? to 1? diameter shafts. |
---|
PS-100 | Pulse width modulation interface for modulating actuators. |
---|
SGA24 | Positioner control for modulating actuators (flush mount). |
---|
SGF24 | Cable conduit connector, 1/2?. |
---|
ADS-100 | Input rescaling module for modulating actuators. |
---|
ZG-R01 | 50% voltage divider kit (resistors with wires). |
---|
ZG-X40 | Cable for ZTH US to actuators w/o diagnostics socket. |
---|
PTA-250 | Positioner control for modualting actuators (surface mount). |
---|
IRM-100 | Belimo MFT configuration software (hardware not included). |
---|
IND-AFB | AFB(X)/NFB(X) position indicator. |
---|
KG8 | Ball joint for 5/16? diameter rod, 90�, galvanized steel. |
---|
KH-AFB | Push rod for KG10A ball joint (36? L, 3/8? diameter). |
---|
ZG-AFB118 | Damper clip for damper blade, 3.5? width. |
---|
KG10A | Ball joint for 3/8? diameter rod, zinc plated. |
---|
KH10 | Univ. crankarm, slot 21/64? w, for 9/16? to 1? dia. shafts. |
---|
SH10 | Push rod for KG6 & KG8 ball joints (36? L, 5/16? diameter). |
---|
ZG-120 | AFB(X)/NFB(X) crankarm adaptor kit. |
---|
ZG-JSA-3 | Weather shield - galvaneal (13? L x 8? W x 6? D). |
---|
TF-CC US | BACnet gateway module for up to 8 MFT actuators. |
---|
UK24BAC | LON gateway module for up to 8 MFT actuators. |
---|
UK24LON | MODbus gateway module for up to 8 MFT actuators. |
---|
UK24MOD | 4 to 20 mA adaptor, 500�, 1/4 W resistor w 6? pigtail wires. |
---|
ZG-R02 | Mounting plate for SGF. |
---|
ZG-SGF | 120 to 24 VAC, 40 VA transformer. |
---|
ZG-109 | Stand-off bracket for ZS-260. |
---|
ZG-110 | AFB(X)/NFB(X) U bracket (5-7/8? H x 5-1/2? W x 2-19/32? D). |
---|
ZG-JSA-1 | 1-5/16? diameter jackshaft adaptor (12? L). |
---|
ZG-JSA-2 | 1.05? diameter jackshaft adaptor (12? L). |
---|
ZS-101 | Weather shield - PC w/ foam seal (16? L x 8-3/8? W x 4? D). |
---|
ZS-300-5 | 1/2? shaft adaptor, standard wtih ZS-300(-5). |
---|
ZS-300-C1 | 3/4? shaft adaptor for ZS-300(-5). |
---|
ZS-300-C2 | 1? shaft adaptor for ZS-300(-5). |
---|
ZS-300-C3 | 20 piece Z-AF kit. |
---|
K7-2 | Standard AFB(X)/NFB(X) clamp (1/2? to 1.05?). |
---|
KH12 | Univ. crankarm,slot 21/64? w,for 3/8? to 11/16? dia. shafts. |
---|
KH8 | AFB(X)/NFB(X) crankarm (with 3/4? dia. shaft pass through). |
---|
Z-AF | Univ. right angle bracket (17? H x 11-1/8? W x 6? base). |
---|
ZG-118 | Jackshaft mounting bracket. |
---|
ZG-AFB | AFB(X)/NFB(X) crankarm adaptor kit. |
---|
Z-SF | Analog to digital switch for modulating actuators. |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|