120VAC ON/OFF 180in# S/R ACTApplication | The FSAF_A actuators provide true spring return operation for reliable fail-safe
application and positive close-off on UL555S dampers. The spring return
system provides constant torque to the damper with and without power applied
to the actuator. The FSAF_A series provides 95� of rotation and is provided with
a graduated position indicator showing 0 to 95�. |
---|
Servicing | maintenance free |
---|
Power Supply | 120 VAC � 10%, 50/60 Hz |
---|
Power Consumption Running | 28 W, 38 VA |
---|
Power Consumption Holding | 10 W, 24 VA, End stop 54 VA, 0.5 A slow
blow fuse |
---|
Electrical Connection | 3 ft, 18 GA appliance cable, 1/2? conduit
connector |
---|
Overload Protection | electronic throughout 0� to 95� rotation |
---|
Direction of Rotation (Motor) | can be selected by CCW/CW mounting |
---|
Running Time (Motor) | <25 seconds |
---|
Ambient Temperature Range | 32�F to 122�F [0�C to 50�C] |
---|
Storage Temperature Range | -40�F to 176�F [-40�C to 80�C] |
---|
Housing | NEMA type 1 / IP40 |
---|
Agency Listings | cULus listed to UL60730-1A:02; UL 60730-
2-14:02 and CAN/CSA-E60730-1:02; Listed
to UL 2043 - suitable for use in air plenums
per Section 300.22(c) of the NEC and Section
602.2 of the IMC |
---|
Noise Level (Motor) | Inaudible holding, running <40 dB (A) spring
<62 dB (A) |
---|
Quality Standard | ISO 9001, RoHS (EU-Directive 2011/65/EU) |
---|
Direction of Rotation (Fail-Safe | can be selected by CCW/CW mounting |
---|
Position Indication | visual indicator, 0� to 95� (0� is full spring
return position) |
---|
Running Time (Fail-Safe) | <15 seconds at ambient temperature |
---|
Noise Level (Fail-Safe) | inaudible holding, spring 73 dB (A) |
---|
Housing Material | zinc coated steel |
---|
Electrical protection | grounded enclosure, 120V |
---|
Humidity | 5 to 95% RH non condensing (EN 60730-1) |
---|
Shaft Diameter | 1/2? to 1.05? round, centers on 3/4? with
insert, 1.05? without insert |
---|
Gears | steel, permanently lubricated |
---|
Torque (US unit) | 180 in-lbs [20 Nm] minimum |
---|
BAE165 US | 165� F electric thermal sensor, SPST, normally closed. |
---|
S2A-F US | Auxiliary switch, 2x SPDT, 3A (0.5A inductive) @250 VAC max |
---|
AF-P | Anti-rotation bracket AF/NF. |
---|
SH8 | Push rod for KG6 & KG8 ball joints (36? L, 5/16? diameter). |
---|
ZG-100 | Univ. right angle bracket (17? H x 11-1/8? W x 6? base). |
---|
ZG-101 | Univ. right angle bracket (13? H x 11? W x 7-7/16? base). |
---|
ZS-100 | Weather shield - galvaneal (13? L x 8? W x 6? D). |
---|
ZS-150 | Weather shield - PC w/ foam seal (16? L x 8-3/8? W x 4? D). |
---|
ZS-260 | Explosion proof housing. |
---|
ZS-300 | NEMA 4X, 304 stainless steel enclosure. |
---|
TOOL-06 | 8 mm and 10 mm wrench. |
---|
ZG-102 | Dual actuator mounting bracket. |
---|
IND-AFB | AFB(X)/NFB(X) position indicator. |
---|
KG8 | Ball joint for 5/16? diameter rod, 90�, galvanized steel. |
---|
KH-AFB | AFB(X)/NFB(X) crankarm (with 3/4? dia. shaft pass through). |
---|
ZG-AF | US Classic AF/NF crankarm adaptor kit. |
---|
ZG-AFB118 | AFB(X)/NFB(X) crankarm adaptor kit. |
---|
Operation | The FSAF_A series actuators are mounted to the damper axle shaft or jackshaft
(1/2? to 1.05?) via a cold-weld clamp. Teeth in the clamp and V-bolt dig into
the metal of both solid and hollow shafts maintaining a perfect connection. The
specially designed clamp will not crush hollow shafts. The bottom end of the
actuator is held by an anti-rotation strap or by a stud provided by the damper
manufacturer. The actuator is mounted in its fail safe position with the damper
blade(s) closed. Upon applying power, the actuator drives the damper to the
open position. The internal spring is tensioned at the same time. If the power
supply is interrupted, the spring moves the damper back to its fail-safe position.
Note on linkage kits.The correct leg kit for the FSAF_A series is the older ZGAF
US as the actuator has a classic AF frame. However, the spline is the new
generation type and the crank arm required is the KH-AFB. |
---|
Typical Specification | All smoke and combination fire and smoke dampers shall be provided with Belimo FSTF, FSLF, FSNF, or FSAF actuators. All substitutions must be approved before submission of bid. Damper and actuator shall have UL 555S Listing for 250�F &/or 350�F. Actuator shall have been tested to UL 2043 per requirements of IMC 602.2 and NEC 300.22 (c). Where position indication is required -S models with auxiliary switches or damper blade switches will be provided per code requirements. |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|