The ICM492 constantly monitors line voltage and protects single-phase equipment against low and high voltage conditions, and rapid short cycling due to voltage fault or power interruption. Its easy-view, backlit digital display makes it user friendly to read and monitor voltage conditions, and adjust parameters to meet specific needs.* Protects Against Over and Under Voltage, and Rapid Short Cycling caused by Transient Faults and Power Interruptions* Easy-view, Backlit Digital Display * RMS Voltage Monitoring * Adjustable Voltage Set Point * Adjustable Over Voltage Setting * Adjustable Under Voltage Setting * Adjustable Anti-Short Cycle Time Delay * Adjustable Response Time * Control Mode * 5-Fault Memory * Universal Line voltage Input * Heavy Duty SPDT Relay Output * Universal Control Voltage Input for integrating a thermostat
WEIGHT/DIMENSIONS:
Weight: 0.4
Height: 1.35
Width: 3.2
Length: 3
SPECIFICATIONS:
User Adjustable Settings:
- Voltage setpoint: 95-280 VAC
- Anti-short cycle time delay: 0-720 seconds
- Over voltage setting: 5-25%
- Under voltage setting: 5-25%
- Control mode: On and Off
- Response time: 0.1 to 10 seconds
Inputs:
- Voltage: 80 to 300 VAC
- Frequency: 50/60 Hz
- Accuracy: ±2%
- Low Power Consumption: max 50 mA @ 120V, max 100 mA @ 240V
- Control Voltage: 18 to 240 VAC
Output:
- Type: Dry relay contacts
- Form: SPDT
- Relay Contact Ratings:
- N.C. Contacts: 10A resistive @ 277 VAC
- N.O. Contacts: 10A resistive @ 277 VAC
- Connection Terminals: 0.25” male fast-on
Environmental:
- Operating temperature range: -40°C to +70°C
- Storage temperature range: -40°C to +85°C
- Maximum Operating/Storage Relative Humidity: 95% non-condensingDigital single-phase line voltage monitor; fully programmble with 5-fault memory; protects against under/over voltage, rapid short cycling; 80-300 VAC (24-240 control VAC). Monitors line voltage and protects single-phase equipment against low and high volWebsite | https://www.icmcontrols.com/product/icm492/ |
---|
Harmonized Tariff Schedule Code | 8536.30.4000 |
---|
P65 indicator | Warning: Cancer and reproductive harm. For more information go to www.p65warnings.ca.gov |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|