• Input from DCV C02 sensor provides optimum ventilation based on occupancy.
• All models include air change and shutdown; "A" models also provide prepurge.
• Demand control ventilation economizer provides comfort, energy savings, reliability, air quality compliance and application flexibility in heating, cooling and ventilating applications.
• Combines solid state enthalpy or dry bulb changeover control, minimum and maximum damper position potentiometer and DCV setpoint functions.
• Optional differential enthalpy control (enthalpy setpoint D with two C7400A sensors) provides greater economizer savings and maximum comfort over single enthalpy control by selecting the most economical method for cooling.
• Enthalpy setpoint (A-D) on economizer module controls the combination of air temperature and humidity that is suitable for free cooling.
• LEDs indicates when economizer is in free cooling and DCV modes.
• B models provide for input from an outdoor air quality sensor.Enhanced Economizer Logic Modules, 2-10 Vdc to ActuatorApprovals, Others | Complies with California Title 24 |
---|
Output | 2-10 Vdc to actuator |
---|
Input | Discharge Air Temperature sensor: C7150 or C7046 |
---|
Approvals, C-Tick | Approved |
---|
Overview | Use with C7400A, or C7660 and C7150B or C7046 Sensors; Demand Control Ventilation (DCV) sensor C7232 C02 sensor (2-10 Vdc); and Honeywell Series 72 actuators, or M7415 Damper Actuator to proportion outdoor and return air dampers for economizer and ventilation control in commercial HVAC equipment. (See below) |
---|
Contact Ratings | 1.5 A Run @ 30 Vac |
---|
Approvals, CE | CE Report: GV02-003 |
---|
Operating Temperature Range (F) | -25 F to +125 F |
---|
Operating Temperature Range (C) | -32 C to +52 C |
---|
Comments | Can accept remote minimum position damper position potentiometer and/or analog input from one carbon dioxide sensor for indoor air. |
---|
Dimensions (in.) | 8 11/16 in. high x 5 13/16 in. wide x 1 11/16 in. deep |
---|
Dimensions (mm) | 221 mm high x 147 mm wide x 43 mm deep |
---|
Operating Humidity Range (% RH) | 5 to 95% RH, non-condensing |
---|
Approvals, Underwriters Laboratories Inc | UL Listed File: E4436, Guide: XAPX, Meets UL873 plenum requirements |
---|
Used With | Honeywell Series 72 actuators |
---|
Product Family
All orders are shipped same-day if the order is received by 1:00 PM Central Time. We ship worldwide.
UPS Hoilday Delivery Schedule
For more infomation about Returns visit Returns
For more informatrion about Warranty visit Warranty page.
You can also find answers to some common questions on our FAQ page
Reviews
Not reviewed yet, be the first to write one!
Add Review
|